Home > Hot Tub > Hot Tub Error Code List Sns

Hot Tub Error Code List Sns

Contents

The "SF" Safety Fault Error Message indicates that the Vacuum Switch has closed, indicating that there has been a Suction Problem or a Possible Entrapment Situation Avoided.2. Back to Top SF or SAFETY FAULT Message There is a "Safety Fault" (SF) condition on a spa with a pump suction blockage switch.On a spa with a pump suction blockage Pr This message is displayed when your hot tub is first powered on. Note: A common programming mistake is overlapping filter times that may cause the spa to filter continuously.• Check the water level.• Check the water temperature with an accurate temperature thermometer. http://indowebglobal.com/hot-tub/hot-tub-error-code-sl.html

Shut the power down, remove the two wires to the pressure switch/flow switch, find some sort of wire to join the wires, but don't do it yet. FL Spa water is more than 20° F cooler than the temperature set point. Ecn The hot tub is in Economy mode While in this mode your hot tub will only heat while it filters. No action is necessary.

Balboa Hot Tub Codes Sl

Test the Sensors, or Continue for a Detailed Test Procedure. However, the usual cause for spa temp sensor error codes is that the water flow is insufficient, and when water moves too slowly through the heater, it doesn't remove the heat Master Spa Parts 2140 W. I CE2 = Freeze protection.

Back to Top OHS, OH, or SPA TEMP LMT Message There is an "Over Heated Spa" (OHS or OH) Water Condition.One of the Water Temp Sensors has detected 110°F (43.3°C) Incoming Depending on where the temp sensor is mounted; usually in the wall of the spa in a sensor mount, you could have a flow issue. This may cause your water temp to not be at what you have it set at. Balboa Sn Error Code Pictured here is a Balboa® control system used in Belize Spas brand.

If one of these sensors needs to be replaced BOTH should be replaced at the same time. Switch closed while pump is deactivated.COL = Cool condition. Sn3 Open or shorted sensor ( heater disabled). If flashing by itself, spa is shut down.The Panel Displays Cd, CLd:This indicates that a sensor detects a possible freeze condition.

Do not enter the spa. Cal Spa Hot Tub Error Codes Like the name says, it was quite easy to install." James Hirsch Buffalo, NY Balboa is a trademark of Balboa Instruments - Manufacturer of Control Systems for Spas Get Contact your Dealer or Service Organization.SnS or Sn is Blinking ON and OFF:There is a Verified "Sensors out of Sync" (SnS or Sn) with Each Other Condition. In rare cases (usually warmer climates), the circulation pump may also cause overheating.

How To Fix Sn Code On Hot Tub

Other Heating Modes are Standard, Standard in Economy, and Sleep Modes.Ecn or Ec is ON Solid (Not Flashing):The Current Water Temperature is "Unknown" (- - - or - -) while in click resources Could indicate a flow problem. Balboa Hot Tub Codes Sl No action is necessary. Balboa Hot Tub Error Codes Remove spa cover and let the water cool down.

These will present themselves in many forms on the display, such as Sn, Sn1, Sn2, and they refer to temperature sensors located on the heater manifold. http://indowebglobal.com/hot-tub/hl-error-code.html The first thing you want to do before doing anything else is shut the spa down, remove the filter and make sure all the jets are open. Dream Maker Hot Tubs OH = Overheat 108° F, spa is deactivated. PSoH = Pressure switch open with high pump. Sn Error Code Hot Tub

Too Many Closed Jets.6. ACC (Applied Computer Controls)Systems for Spas or Hot Tubs: CoLd = Temperature in the spa heater housing is below 40° F. Dirty Filter.5. his comment is here Heater is deactivated.FL1 = Water flow problem, inhibited or pressure switch malfunction.

The Sensors are Verified Out of Sync with Each Other, or Not Indicating Close to the Same Temperature at Both Sensors. Cal Spa Sn Error Code These are similar to the Sn1 and Sn2 codes, signaled from the high limit or water temperature sensors. If it is hot you have a flow issue, or if it stays hot after the pump is shut off either the pressure switch has stuck close (see FLO error codes

The most common valve; the tee handle valve (also known as gate or slice valve), will show that the handle is up, but in many cases the gate is still half

Turn the power back on, you have five seconds to join the wires together, do not join them before you turn the power on. The controller display is telling you that either the high limit or the temp sensor are open or shorted. Heater is deactivated.Sn2 = Nonfunctional temperature sensor. Balboa Hot Tub Codes F8 Make sure that they are open.

Spa is shut down.Pr = When spa is first actuated, it will go into Priming Mode.ILOC = Interlock failure - possible pump or ozone spike .(---) =Unknown water temperature. (Displays when Contact qualified service technician. HL High limit switch tripped. weblink To read the Current Water Temperature, either Change to Standard Heating Mode or turn On the Heating Related Pump, and wait at least 2 Minutes.

SN, Sn1, Sn2 Sn3, HL, E1, E3, Prh, HtS, Blinking Lights Hi Limit Sensor Failure. OH = Overheating, water over 112° F. If there is Now a "CrC" or "CHKSUM FAIL" Error Message, contact your Dealer or Service Organization. The "SnS", "Sn", or "SENSOR SYNC" Fault has occurred for more than 1 hour, indicating one or both Sensors are several degrees off, and Spa Functions are Disabled.

All Products ... HLoH Hi Limit Over Heat. If all these test are checked and they did not solve the error code issues, then it is possible you have a defective hi limit sensor. Remove the spa cover and allow the water to cool to below 42.0° C.

Heater is deactivated. Pumps and Blower can be turned ON and OFF to Remove any Air from the Heater. Back to Top rdr or DRAIN WATER Message Time to "Drain Spa Water Reminder" (rdr).Appears Every 90 Days*. Back to Top CrC or CHKSUM FAIL Message "Cyclic Redundancy Code" (CrC) Checksum Error.A "Cyclic Redundancy Code" (CrC) is a type of checksum algorithm that takes a string of data bytes

Flow switches are plumbed in line with the plumbing. See M7 Sensors here. Shop By Categories Accessories Air Controls Chemicals Spa Boss Cleaners Spa Boss Sanitizers SpaBoss Water Balancers Spa Crystals Fragrances Circuit Boards Control Packs Covers Clarity Spa Covers Down East Spa Covers Doing so may cause damage to the pump and cause the system to go into an overheat condition.If after repeated attempts (hours apart) you still cannot get all pumps to prime,

As a responsible adult, always check the topside control panel display for errors and verify safe water temperature before using a spa, and before allowing children to use a spa. If it is hot you have a flow issue, or if it stays hot after the pump is shut off either the pressure switch has stuck close (see FLO error codes I have you guys bookmarked now for all my hot tub needs and will be referring others to ur site because of ur prompt service and very reasonable prices." - Sarah Consumer Reviews EasyPak Spa Controls "Very pleased with the ease of installation and all the diagnostic features that other spa packs did not even have.

One sensor has detected 118º F. Then power the system back up, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. Or, it could be a problem with the thermostat allowing the heater element overheat.