Spa is shut down. Switch closed while pump is deactivated.COL = Cool condition. ICE Freeze protection. Sometimes, it's actually a bad pressure switch or flow switch, or loose connections or damaged wires or wire connectors. his comment is here

drops. You can leave a response, or trackback from your own site. For Low Flow spa error codes, check the filter, check the pump and check the valves to find something that is obstructing the water flow. Happy Hot Tubbin' Daniel Lara Hot Tub Works Tags: spa error codes, Spa Heater Elements, spa heaters This entry was posted on Tuesday, January 6th, 2015 at 6:58 am and

Balboa Hot Tub Error Codes

I CE2 = Freeze protection. Check for proper water level and for clogged filter (pages 60-62). Flo = Improper flow or pressure switch malfunction Cool = Water temp 20° below set point ICE = Potential freeze condition has been detected Sn1 = Hi-limit sensor malfunction Sn3 = SESH = Sensor short, nonfunctional.

The Spa or Hot Tub Panel Displays: Sn, SnS This indicates that the sensors are out of balance.If alternating with temperature, it may just be a temporary condition. dry = Inadequate water detected in heater. (Displays on third occurrence of "dr" message). Do not use spa when temperature is flashing or the OH message is displayed. Coleman Spa Error Codes LF Persistent low flow problems. (Displays on the 5th occurrence of "HFL" message with 24 hours).

HL = High limit switch tripped. Heater is shut down, but other spa functions run normally. Contact qualified service technician. https://spacare.com/spasideerrorcodes.aspx Rotomolded Spas Spa Preppers - Hurricane Spa Protection Hot Tub Circulation Pump Troubleshooting How to Measure for a Hot Tub Cover Hot Tub Electrical Safety Spa & Hot Tub Plumbing Fittings

Shut the spa power off, remove the filter and make sure all the jets are open. Hot Tub Error Code Oh Switch closed while pump is deactivated. The final problem could be the pressure switch/flow switch itself. OH Overheating, water over 112° F.

Vita Spa Error Codes

Other issues that can cause these error codes one or more of the service valves is not open up all the way. http://www.hottubworks.com/blog/spa-hot-tub-error-codes-fl-flo-flow-lf/ OPEN or SHORTED SENSOR (heater disabled) The main temperature sensor is non-functional. Balboa Hot Tub Error Codes Gecko Error Codes also cover any control box manufactured by Gecko.For information regarding repairs click here If you need further help with troubleshooting click here Balboa | Gecko | Hurricane | Marquis Spa Error Codes If flashing by itself, spa is shut down.

If water temperature drops 20ºF below set temperature, low speed pump and heater activates to bring temperature within 15º of set temperature. http://indowebglobal.com/error-code/honeywell-error-codes.html PSoC Pressure switch open with circulating pump. Make sure that all jets are open, and nothing is blocking the spa drain cover flow. FLO Flow Switch (heater is deactivated. How To Fix Flo Error Hot Tub

Heater is deactivated. The alphabetical list of hot tub error codes below covers all major manufacturers of spa controls, including ACC, Balboa, Brett Aqualine, CTI, Dream Maker, EasyPak, Gecko, Hurricane, Jacuzzi, Len Gordon, Maax, Note: This auxiliary freeze protection functions at all times, even when another fault condition has occurred and has otherwise shut the spa down. http://indowebglobal.com/error-code/hot-tub-error-codes-fl1.html The hot tub will stay in this mode until the water temperature reaching 15 degrees below the set temperature.

Rare system error. Gecko Spa Pack Error Codes NOTE: Temperature sensors should be mounted in a sensor mount in the wall of the spa and not behind the shield on the heater manifold with the hi limit sensor. OH Over heat.

Blue Ridge Spa Side Error Codes click here Gatsby Spa Spa Side Error Codes click here Imperial Spa Spa Side Error Codes click here Swift River Spa Side Error Codes click

Pump may also be deactivated). Std = Spa operating in Standard Mode. Water temperature is above acceptable limits.DO NOT ENTER THE WATER! Coast Spa Error Codes HOT Circuit Board temperature has exceeded acceptable limit.

UV bulb needs to be replaced. This must be repaired only be a Sundance Spas dealer or qualified service technician. Sending a digital picture is very helpful in helping us to troubleshoot or answer any questions. check over here OH, or OHH, or OHS (Overheat) all mean that a temperature sensor has detected unsafe water temperatures of 108° - 118° F, and your spa is in an emergency cool down

Proceed step by step, and you should be able to find the cause of the FL, FLO or FLOW error code. You can also check the pressure switch or flow switch with a an Ohm meter. Remove hot tub cover to speed cooling. Then power the system back up, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off.

You must be logged in to post a comment. FL1 = Water flow problem, inhibited or pressure switch malfunction. Sn2 Nonfunctional temperature sensor. Problem is - there's not much consistency among the error codes used by spa pack manufacturers.

The Spa or Hot Tub Panel Displays: dr, dry This indicates that there is not enough water in the heater. Sensor plugged into jack B is not working. Refer to your owner's manual. Status of the heater element is unknown.

The most common valve; the tee handle valve, will show that the handle is up, but in many cases the gate is still half closed, make sure that it is open Turn the power back on, you have five seconds to join the wires together, do not join them before you turn the power on.