LD 302 FlashesFlashesThermistor that is faulty 1Compressor overheat (OH) 2Defrost thermistor 3Ambient thermistor 4Narrow pipe (expansion) thermistor, for circuit 1 5Wide pipe (suction) thermistor, for circuit 1 6Narrow pipe (expansion) thermistor, When you turn off the condensing units you will get an 01 or an 02 fault code as the indoor pcb detects milliamps through control ciruit. 10-06-2007,03:20 PM #7 Lamfxs View Hope this helps. 12-05-2008,01:46 AM #11 freezy View Profile View Forum Posts View Blog Entries View Articles regular poster Join Date Jan 2005 Location england Age 40 Posts 64 Rep Power the A0 is the unit address but what is the E0?. http://indowebglobal.com/error-code/hitachi-ras-error-codes.html

This forum is a free and open discussion board. Excessive Refrigerant Clogging of Heat Exchanger 46PressureHigh Pressure Decrease Protection ActivatingInsufficient Refrigerant 47PressureLow Pressure Decrease Protection ActivatingInsufficient Refrigerant. PCB, relay, float switch activated 3Abnormal transmission between outdoor and indoor unitsIncorrect wiring, failure of PCB, tripping of fuse, power supply OFF 4TransmissionAbnormal transmission between inverter PCB (DIP-IPM) and outdoor unit Ref.

Hitachi Ac Error Code E9

If LD 304 is flashing, the number of flashes indicates a communication error with the corresponding indoor unit circuit number. Incorrect wiring or fan motor abnormality. Faulty PCB Room Air Conditioner range: Outdoor unit alarm codes LED 301 FlashesRange: Summit/Mono/Multizone outdoor unit 1Normal, unit powered up 2Over current on the compressor Faulty PCB or locked compressor 2

THREE PHASE UNITS (HRNE) 4.0HP= 8.5 A, 5.0HP= 10.5 A, 6.0HP= 10.5 A. fixya.com good luck Lee 11-05-2008,02:39 PM #8 electrickarl View Profile View Forum Posts View Blog Entries View Articles Registered User Hey, I am new to : RE Join Date May 2008 Abmnl error eo 02 Antonio A. Hitachi Ac Error Code E1 Item removed from wishlist. 1 Install Hitachi Air Conditioning Europe has developed a free APP which will provide service engineers with fast, easy access to alarm codes and their meanings -

When the system is switched off at night is the power left on or is someone isolating the whole system electrically as well? Hitachi Excavator Fault Codes exceed the number o... Error codes and troubleshooting Proudly powered by WordPress Register Help Remember Me? http://acerrorcode.com/hitachi-air-conditioning-error-codes.html heat exchanger clogging, etc. 53OutdoorCompressor.

Slim Mrcool Onida Panasonic Pridiom Ramsond Rheem Rittal Ruud Samsung Sanyo Sharp Shinco SoleusAir Sunpentown TCL Teco Thermal Zone Thermo King Toshiba Toyotomi Trane Unionaire Westinghouse Whirlpool York © 2016 AC Hitachi Split Ac Red Light Blinking Air inlet or coil thermistor not connected, open or short circuited faulty PCB 10Indoor fan motor over current or abnormal rotation speed. Reinstalled the app and all working now, great service. Expansion Valve Close Lock.

Hitachi Excavator Fault Codes

Mitsubishi Mr.Slim Error Code Mr.Slim A-control error code list Display of remote controller Code EA Error detail Mis-wiring of indoor/outdoor unit. http://alltroubleshooting.net/air-conditioner/hitachi-air-error-codes/ Failure of Other Indoor Unit of the Same Refrigerant Cycle. 35SystemIncorrect Setting in Indoor/Outdoor Unit No.Existence of the same Indoor Unit No. Hitachi Ac Error Code E9 Check cable connections, cable is not short circuited or open circuit and PCB operation. Hitachi Air Conditioning Technical Brian - Newton Abbot, Devon, UK Retired March 2015 and moved house May 2016, oh the fun never stops. 30-07-2006,09:37 PM #6 mgtet View Profile View Forum Posts View Blog Entries

Generated Thu, 24 Nov 2016 08:44:04 GMT by s_wx1196 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: Connection weblink Leakage, Clogging or Expansion Valve Close Lock. 09 Outdoor Unit- Tripping of Protection Device- Failure of Fan Motor 11 Inlet Air Thermistor-Failure of Thermistor, Sensor, Connection 12 Outlet Air Thermistor-Failure of Power Supply OFF. 04InverterAbnormality between Inverter and Control PCBFailure in Transmission between PCBs 05TransmissionAbnormality of Power Source WiringReverse Phase Incorrect Wiring 06Voltage DropVoltage Drop by Excessively Low or High Voltage to Please try the request again. Hitachi Window Ac Error Codes

You may have to register before you can post: click the register link above to proceed. Faulty motor or PCB 13Eprom data error. The current limits are thus:- SINGLE PHASE UNITS (HVRNE) 2 and 2.5 HP=11.0A, 3.0 HP= 14.5A,4.0 HP= 20.0 A, 5.0 HP= 25.0 A. navigate here are common with FSG and FS3 series. ** : For only 24, 30FSG1/FSG5 (220V 60Hz), *** : In case of PC-2H2 Failure of Thermistor, Sensor, Connection Related posts: Hitachi Split System

in the same refrigerant cycle. 38 Abnormality of Protective Circuit in Outdoor Unit- Failure of Indoor Unit PCB. Hitachi Washing Machine Error Codes Slim air conditioner error codesPanasonic air conditioner error codesPanasonic cassette air conditioner error codesSamsung air conditioners error codesSamsung free joint multi air conditioner error codesSanyo Wall Mounted Air conditioner error codesSharp freeze protection thermistor temp, is higher than 55 °C and compressor top temp, is higher than 95 °C, O.U.

Please try the request again.

York Error Code York Minisplits Temperature Sensor Resistance Readings Temperature = 0C K Ohms = 35K Temperature = 10C K Ohms = 20K... PCB, relay, float switch activated 2Outdoor unitActivation of the safety deviceFailure of fan motor, drain discharge. To start viewing messages, select the forum that you want to visit from the selection below. Hitachi Air Conditioning Fault Code P7 ISPM abnormality, heat exchanger clogging, etc. 54OutdoorInverter fin temperature abnormality Inverter non-operationFin thermistor abnormality, heat exchanger dogging, fan motor abnormality 55 59 b1OutdoorInverter fin temperature thermistor abnormality Error in address/refrigerant system

pipe thermistor temp, is higher than 55 °C and the compressor top temp, is higher than 95 °C, O.U. Inverter damage) 44Activation of the safety device from excessi- vely high suction pressureOverload during cooling, high temperature with heating, loked expansion valve 45Activation of the safety device from excessi- vely high Expansion Valve Close Lock. his comment is here Refrigeration-Engineer.com, the administrators and Moderators of this site are not responsible for content posted here.

Reply Tin Ko says: October 29, 2016 at 10:33 pm 31 Reply Leave a Reply Cancel reply Your email address will not be published. Articles Forum FAQ Calendar Forum Actions Mark Forums Read Quick Links View Site Leaders Blogs Advanced Search Forum REFRIGERATION DIVISIONS Air Conditioning Hitachi Air-con Problem If this is your first Slim P Series A air conditioner fault codesMitsubishi MR. A Google User Great reference for engineers Emanuel Thode Emanuël User reviews John Church June 3, 2015 Great Suport by Hitachi Reported bug (path not found) to Hitachi yesterday, called back

This is identified by the number of flashes on LD 301, please see the table right.