Home > Error Code > Hitachi Ac Error Codes

Hitachi Ac Error Codes

Contents

Sign in to report inappropriate content. pipe thermistor temp, is higher than 55 °C and the compressor top temp, is higher than 95 °C, O.U. Sign in 5 0 Don't like this video? If the systems are shut off overnight when switched on the following morning they run for a short time then shut down with the following fault code: A0 E0 O1 on http://indowebglobal.com/error-code/hitachi-ras-error-codes.html

AdamDIY 105,012 views 3:41 ac servicing (split ac outdoor pm) - Duration: 14:09. Reversing valve or coil thermistor is faulty 02Forced operation from the outdoor unit. Display will flash as shown in diagram. Tripping of Fuse.

Hitachi Ac Error Code E9

some installations wire the external condensate pump safety switch into the unit. in the same refrigerant cycle. 38SystemAbnormality of Protective Circuit in Outdoor UnitFailure of Indoor Unit PCB. By THERMOACC in forum Trouble Shooting Replies: 2 Last Post: 28-05-2006, 09:39 AM hitachi ducted problems By Krups in forum Air Conditioning Replies: 16 Last Post: 01-09-2005, 07:40 PM LG 10.5 Check cable connections, cable is not short circuited or open circuit and PCB operation.

This is not an error 03Communication error. The time now is 10:10 AM. consumer voice 1,711 views 3:08 Homemade air conditioner DIY - Awesome Air Cooler! - EASY Instructions - can be solar powered! - Duration: 5:32. Hitachi Ac Error Code E1 Loading...

The Japanese conglomerate company produces goods in more than ten segments, from electronics and information systems to railway and automotive systems. If LD 303 is on permanently this is normal operation. If timer lamp flashes for a number of times and then pauses, please reference table below. I think your unit may be a RAS-HVRNE or RAS-HRNE.

Loading... Hitachi Split Ac Red Light Blinking On Multizone systems only, if LD 301 is lit permanently and LD 302 is flashing a number of times, this indicates a thermistor fault. If LD 301 is lit in conjunction with LD 303 his indicates an overload (1) condition but not an alarm. The table below contains the error codes for Hitachi air conditioning systems, explained in all details.

Hitachi Air Conditioning Technical

Please refer to the table right for the thermistor that is faulty. http://errorcodeairconditioning.blogspot.com/2010/10/hitachi-error-codes.html When the system is switched off at night is the power left on or is someone isolating the whole system electrically as well? Hitachi Ac Error Code E9 This is identified by the number of flashes on LD 301, please see the table right. Hitachi Excavator Fault Codes Watch Queue Queue __count__/__total__ Find out whyClose Hitachi Air Conditioning Mobile app for identifying product Alarm Codes Hitachi Air Conditioning Europe SAS SubscribeSubscribedUnsubscribe138138 Loading...

Faulty wiring, indoor or outdoor PCB faulty 04Outdoor unit fault. check over here It is listed in the Forbes rankings of the world’s most influential companies on a regular basis. Inverter damage) 44Activation of the safety device from excessi- vely high suction pressureOverload during cooling, high temperature with heating, loked expansion valve 45Activation of the safety device from excessi- vely high Slim P Series K air conditioner fault codesMitsubishi PWFY air conditioner fault codesPanasonic air conditioning fault codesToshiba air conditioning fault codesService & MaintenanceCauses of Air Conditioner FailureMobile Air Conditioner safetyPortable air Hitachi Window Ac Error Codes

Added to Wishlist Remove Removing... Results 1 to 11 of 11 Thread: Hitachi Air-con Problem Thread Tools Show Printable Version Subscribe to this Thread… Display Linear Mode Switch to Hybrid Mode Switch to Threaded Mode 24-07-2006,04:44 Mitsubishi Mr.Slim Error Code Mr.Slim A-control error code list Display of remote controller Code EA Error detail Mis-wiring of indoor/outdoor unit. his comment is here heat exchanger clogging, etc. 53OutdoorCompressor.

The current limits are thus:- SINGLE PHASE UNITS (HVRNE) 2 and 2.5 HP=11.0A, 3.0 HP= 14.5A,4.0 HP= 20.0 A, 5.0 HP= 25.0 A. Hitachi Washing Machine Error Codes All Rights Reserved | Template Style by My Blogger Tricks .com | Design by Brian Gardner | Back To Top | Logicool Air Conditioning & Heat Pumps Limited - Hitachi Air are common with FSG and FS3 series. ** : For only 24, 30FSG1/FSG5 (220V 60Hz), *** : In case of PC-2H2 Room Air Conditioner range: Indoor unit alarm codes If timer

Excessive Refrigerant- Clogging of Heat Exchanger 46 High Pressure Decrease Protection Activating- Insufficient Refrigerant 47 Low Pressure Decrease Protection Activating- Insufficient Refrigerant.

exceed the number o... If LD 304 is flashing, the number of flashes indicates a communication error with the corresponding indoor unit circuit number. Incorrect Wiring Connection to PCB in Outdoor Unit 39SystemAbnormality of Running Current at Constant CompressorOvercurrent, Melted Fuse of Failure of Current Sensor 43PressurePressure Ratio Decrease Protection ActivatingFailure of Compressor, Inverter 44PressureLow Hitachi Air Conditioning Fault Code P7 Add to Wishlist Adding...

Sign in to make your opinion count. Item added to wishlist. Category Science & Technology License Standard YouTube License Show more Show less Loading... weblink Leakage, Clogging or Expansion Valve Close Lock. 09 Outdoor Unit- Tripping of Protection Device- Failure of Fan Motor 11 Inlet Air Thermistor-Failure of Thermistor, Sensor, Connection 12 Outlet Air Thermistor-Failure of

ie dirty drip pan,faulty pump? If LD 302 is lit in conjunction with LD 303 this indicates an overload (2) condition but not an alarm and if LD 301 and LD 302 are lit in conjunction NLB Heating & Cooling 5,122 views 14:45 E1 code for Superair split air conditioner - Duration: 3:56. Register Help Remember Me?

TEMCo Industrial 421,976 views 7:21 HVAC | Emerson Check & Charge App | NLB Heating & Cooling | 708-420-1163 - Duration: 14:45.